BASO Valve - New One Not Working

by Marc WardClay Times Sept. 2003
Every once in awhile I get someone who calls up and says; “Hey, that BASO Safety Valve you sent me is no good. I hooked it up and it doesn’t work.” This past week, I had one of those calls…
It started as usual with someone describing how they had the new safety valve installed on the line, hooked up a new thermocouple, pushed the button down, lit the pilot, and got nothing happening, nadda, no gas going to the main burner,….nothing. In this particular incidence, they had folks from the local heating and air company doing the installation. They couldn’t get it to work, so they insisted on putting another valve on the gas line and telling our frantic, “I’ve gotta’ fire my kiln cause I have a show coming up”, potter to send the valve back. So, send it back they did and asked that I take a look at the “defective” valve. I promised I would look at it and perform a bench test. Soon it was on its merry way inside a big brown truck driven by an equally merry member of the Teamsters Union. Shortly, my always faithful, UPS worker-bee delivers the offending valve and I proceed to test it.
It works perfectly.
So, what gives? This isn’t the first time I’ve tried to convince someone that these things aren’t defective outa’ the box. And, in this case, some of the people saying it was defective were professionals in the heating and air business… HVAC is the name for all things that fall into this brand of business (Heating, Ventilation, and Air Conditioning). The HVAC guys say its bad…, so it’s bad. Who’s going to argue?
As with many things in our “fixitnow” technological society, symptoms are often mistaken for the actual problems. When a low gas pressure BASO valve doesn’t work, it better to start off looking at the actual problem than to pay for a new valve (treating the symptom).
A BASO safety valve receives a small millivolt signal produced by the flame on the thermocouple. This signal provides enough electrical current to cause a small magnet to pull a lever over that keeps the plunger in the valve from closing off. Not enough signal, and you can’t get the valve to stay open…. Lose some signal while the burner is on and the plunger drops down and shuts the burner off. The problem is usually the signal, not the valve.
So, before you race out to buy a new valve, there’s a few things you need to try to determine if you want to treat the problem or the symptom.
A thermocouple needs to be in blue flame continuously. Not a sort of blue with some yellow. And, not for 9 seconds out of 10. A blue flame continuously. So, you look at your pilot flame and these conditions exist. There are a few other things to try. The first thing to do is to replace the thermocouple with one you know works. If this doesn’t do the trick, you need to give it a good poke. I’m not talking about using a sharp stick… you need to give the voltage a good poke. You can do this by taking a hand-held propane torch and heating up the tip of the thermocouple until it is glowing hot. Many times, this sorta’ jolts the little electromagnet in the BASO and “wakes” it up from its slumber. If this doesn’t do it, you might try cleaning the contact inside the BASO where the thermocouple goes in. Use a little alcohol on a Q-tip. Oxidation may have built up on this connection and prevents our small electric current from getting through. This can be especially true as with our frantic potter. They lived on the coast with plenty of salt spray in the air. Small electrical currents in the presence of salt can really build up a corrosive film.
Before you tear your system apart to replace the valve, try these tricks to make sure you know where the problem is. Remember, as with a bunch of stuff in life, the “identified” problem is, many times, just the symptom.
Copyright © All rights reserved.
About Us
Serving the Combustion Industry for over 40 years
Address
1925 Alamo Trail • PO Box 1086 • Dandridge TN 37725 US
Contact
(865) 397-2914
info@wardburner.com

We use cookies to enable essential functionality on our website, and analyze website traffic. By clicking Accept you consent to our use of cookies. Read about how we use cookies.

Your Cookie Settings

We use cookies to enable essential functionality on our website, and analyze website traffic. Read about how we use cookies.

Cookie Categories
Essential

These cookies are strictly necessary to provide you with services available through our websites. You cannot refuse these cookies without impacting how our websites function. You can block or delete them by changing your browser settings, as described under the heading "Managing cookies" in the Privacy and Cookies Policy.

Analytics

These cookies collect information that is used in aggregate form to help us understand how our websites are being used or how effective our marketing campaigns are.